10.15 LEAD EDGE ERASE MARGIN ADJUSTMENT
(SP2-101-001)
When: If the lead edge erase margin is not within the
adjustment standard.
Purpose: To maintain a proper lead edge erase margin.
Adjustment Standard:
2.5
±
1.5 mm (0.1
±
0.06")
How: SP2-101-001 changes the erase lamp off timing.
SP2-101-001: Lead Edge Erase
0 - 32 (default = 16, – 8.0 mm to + 8.0 mm), 0.5 mm per step
10.16 LENS HORIZONTAL H.P. ADJUSTMENT
(SP4-011-001~009)
When: If side-to-side registration is not within the
adjustment standard.
Purpose: To maintain proper side-to-side registration from
all feed stations.
Adjustment standard:
0
±
2 mm (0
±
0.08")
How: SP4-011-001~009 changes the lens horizontal
home position.
SP4-011-001~007 and 009 change the lens
horizontal home position used for certain units
(see step 3 below). If registration is not within
the standard when using a certain unit, use one
of these SP modes.
SP4-011-008 is the base adjustment made in
the factory. If this setting is changed by a small
amount, all other SP4-011 settings change
automatically by the same amount. Use this if
the image shift direction (to the front or to the
rear) is the same from all paper feed stations.
1. Make a full size copy from each paper feed station.
2. Check whether side-to-side registration is within the adjustment standard.
Rev. 7/95