Firmware Download
SM 5-3 M000/M009
Service
Tables
7. Click the "Upgrade" button [D].
8. Press "OK" button.
9. Press "OK" button to start processing upgrade.
10. Make sure that the firmware has been completely updated.
Do not turn off the power while updating the Firmware.
5.1.2 FIRMWARE RECOVERY PROCEDURE
The machine will not operate if the upgrade procedure did not work correctly. At this time,
do the following steps.
1. Turn the power off and then on.
2. Do the steps in the above download procedure.
The machine will start the upgrade again.